Kopfleiste überspringen

Crossflow Cooling Tower (FAP Standard)

Pros

  • part load operation possible
  • quiet operation
  • accessible & easy to maintain
  • pre-assembled options available
  • short delivery lead time
  • hanging unglued film fill sheets

SPX Marley® Aquatower (AQ)

Facts

  • In-Air-Flow: single
  • Fan type: axial induced draft
  • Cooling Capacity/Cell: 35 - 554 kW | 6 - 86 m3/h
  • Certified: CTI
  • Material Options: Galv steel/Series 300 SS/FRP
  • Special Options: Small tonnage

Applications

  • HVAC

Pros

  • Simple installation
  • ease of maintenance
  • corrosion resistant
SPX Marley® AV

Facts

  • In-Air-Flow: single
  • Fan type: axial induced draft 
  • Cooling Capacity/Cell: 550 - 3.394 kW | 85 - 526 m3/h 
  • Certified: CTI 
  • Material Options: Galv steel/Series 300 SS 
  • Special Options: Site placement flexibility; space limitations

Applications

  • HVAC
  • Light & Medium Process

Pros

  • Heavy-duty construction
  • ease of maintenance
  • simple installation
  • low drift rate
  • low energy costs
SPX Marley NC®

Facts

  • In-Air-Flow: double
  • Fan type: axial induced draft 
  • Cooling Capacity/Cell: 444 - 6.537 kW | 69 - 1.013 m3/h 
  • Certified: Eurovent/CTI 
  • Material Options: Galv steel/Series 300 SS 
  • Special Options: Low sound, low flow, MOA, single bottom inlet piping

Applications

  • HVAC
  • Refrigeration
  • Light, Medium & Heavy Process
  • Power

Pros

  • Highest single-cell cooling capacity
  • validated sound data
  • lowest drift rates
  • enhanced vibration protection
  • Cold Water Basin SunShield™
  • FM Approved option
SPX Marley NC® Fiberglass

Facts

  • In-Air-Flow: double
  • Fan type: axial induced draft 
  • Cooling Capacity/Cell: 444 - 6.537 kW | 69 - 1013 m3/h
  • Certified: Eurovent/CTI 
  • Material Options: Galv steel/Series 300 SS + FRP 
  • Special Options: Low sound, low flow, MOA, single bottom inlet piping

Applications

  • HVAC
  • Refrigeration
  • Light, Medium & Heavy Process

Pros

  • Low energy costs
  • corrosion resistant
  • lowest drift rates

SPX Marley® NC Everest®

Facts

  • In-Air-Flow: double
  • Fan type: axial induced draft 
  • Cooling Capacity/Cell: 5.763 - 9.623 kW | 893 - 1.491 m3/hr 
  • Certified: Eurovent/CTI 
  • Material Options: Galv steel/Series 300 SS
  • Special Options: Low sound, low flow, MOA, single bottom inlet piping

Applications

  • HVAC
  • Refrigeration
  • Light, Medium & Heavy Process
  • Power

Pros

  • 50% greater cooling capacity than other single-cell, factory-assembled tower
  • up to 60% faster delivery and 80% faster installation, greater site flexibility than field-erected towers
  • lowest available drift rate, integral basin
  • no costly concrete basin construction required
SPX Marley NC® Alpha

Facts

  • In-Air-Flow: double
  • Fan type: axial induced draft 
  • Cooling Capacity/Cell: 419 - 3.967 kW | 65 - 615 m3/h 
  • Certified: Coming soon
  • Material Options: Galv steel/Series 300 SS 
  • Special Options: Poor water quality

Applications

  • HVAC
  • Refrigeration
  • Light, Medium & Heavy Process
  • Power

Pros

  • Ease of maintenance
  • low sound
  • heavy-duty construction
  • low energy costs
SPX Marley® Quadraflow

Facts

  • In-Air-Flow: quadro
  • Fan type: axial induced draft 
  • Cooling Capacity/Cell: 567 - 4.603 kW | 88 - 713 m3/h
  • Certified: CTI 
  • Material Options: Series 300 SS/FRP 
  • Special Options: Low height; knockdown, field assembled

Applications

  • HVAC
  • Refrigeration
  • Light, Medium Process

Pros

  • Ease of maintenance
  • corrosion resistant casing

To the brochures of the SPX products.

UNEX HEATEXCHANGER Engineering GmbH
Lobäckerstraße 60d
7000 Eisenstadt
Austria
+43 2682 63585-0
+43 2682 63585-20
nfnxt

 
Please enter the value you see in the picture in the field.

All fields marked with * are mandatory.

The protection of your personal data is a top priority for us. As a consequence, we handle your data exclusively in strict compliance with data privacy laws (DSGVO, TKG 2003). In the following data privacy policy, we inform you about the most important aspects of how data is handled within the framework of our website.

If you have transmitted your personally identifiable information through this website or by email, such information will only be used in order to conduct correspondence with you as well as for those purposes for which you provided that information. We assure you that your personally identifiable information will not be shared with third parties unless the law requires us to do so.

The data you have provided will only be stored for 12 months or until such point as the purpose for which it was shared has been achieved. Insofar as the law requires that data be stored for a specific period of time, we will comply with such legal provisions. Should you no longer agree to our storing your personally identifiable data, pursuant to your request we will delete such data. If your personal data has changed in the meantime, we will correct that data based upon the information you provide us.
Here you will find our complete privacy policy

Data Privacy Policy

This website uses the following external components: maps, videos and analysis tools which use cookies to collect information about your behavior and help to optimize the website.

Necessary Cookies are always loaded!